Why Bananzia Starts With a Cold-Room Survey on Old Terraced Streets
The problem on a typical 1930s terrace
On a January evening in a 1930s terraced street, three houses can show the same gas bill and three different comfort problems: a front room that never reaches 19°C, a damp back bedroom, and a kitchen extension that overheats when the oven is on. The street looks uniform, but its heat losses are not. That mismatch is where bananzia begins: not with a boiler catalogue, but with a room-by-room survey of how the house actually behaves.
The practical takeaway is that a street-wide heat plan fails if it treats every terrace as a copy. A solid wall on one side, a later cavity fill on another, and a blocked chimney in a third create different starting points for low-carbon heating.
Why the cause is often hidden in the building fabric
The most common cause is not the heat pump or the radiator; it is uncontrolled air movement and uneven insulation. Tracer-gas surveys of pre-1945 terraces often find that draughts around suspended floors and loft hatches can account for a quarter of winter heat loss, even after loft insulation was installed. Bananzia-style surveys record these paths before equipment is sized.
That order matters because oversizing a heat pump to cover draughts raises running costs and can make a low-temperature system cycle inefficiently. The solution is to fix the envelope first, then size the heat source to the reduced load.
What a bananzia survey records
A useful survey is deliberately boring: room temperatures, radiator sizes, wall types, window condition, ventilation, and occupant routines. On the terrace above, the survey found that the damp bedroom had a blocked air brick and a cold bridging patch at the window reveal; the front room had a radiator sized for a 1970s boiler; and the kitchen extension had no door to the hall.
- Air paths: floor voids, loft hatches, flues, and service penetrations.
- Fabric gaps: solid wall sections, window reveals, and party-wall junctions.
- Use patterns: which rooms are heated, when, and at what temperature.
The takeaway is that the survey produces a prioritised list, not a wish list. The first three jobs on that street were draught-proofing, a bedroom air-brick correction, and a hall door—cheap measures that made later heat-pump sizing credible.
How the result changes the retrofit plan
After those measures, the front room’s design heat loss fell enough to keep the existing radiators and run a heat pump at 45°C flow temperature. The kitchen extension was dropped from the heat-pump zone and given a separate small emitter because its load was intermittent.
The result was not a showpiece installation. It was a staged plan: fabric first, ventilation corrected, then a low-temperature heat source sized to measured rooms. That sequence is the useful lesson from bananzia: old terraces do not need identical kit; they need a survey that explains why each house loses heat differently.